Velocity duct sizing chart residential main supply trunk ducts non zoned systems target velocity of 800fpm used listed by air quantity round duct size and nearest square duct size 500cfm 11 ø or 10 x 10 1 300cfm 16 ø or 14 x 16 600cfm 12 ø or 10 x 12 1 400cfm 18 ø or 16 x 16.
Round duct duct sizing chart cfm.
Include fittings in the duct tel enter either.
The table is based on the ducts friction loss formula.
Duct system sizes and airflow quick chart created date.
Sheet metal duct friction loss calculator.
Convert rectangular duct to round equivalent.
Air volume equivalent round air volume cfm 4 6 8 10 12 duct inches cfm 50 6 x 4 550 75 6 x 4 675 100 8 x 4 6 x.
Enter duct airflow cfm duct velocity fpm duct length and the number of bends.
The table below can be used to compare equivalent diameters for rectangular and round circular ducts.
The equivalent diameter is the diameter of a circular duct or pipe that gives the same pressure loss as an equivalent rectangular duct or pipe.
Read round duct diameter inches and friction loss per 100 of duct inches of water.
Approximately 400 cfm per ton would require 2 14 flexible return ducts or 1 very short flexible.
While a duct sizing calculator built for a specific type of ductwork is the best possible method for sizing ducts the attached chart can be used in most single story homes with a centrally located unit and reasonable length duct runs.
Larger volumes or higher static pressures should be dealt with on an individual job basis.
Convert diameter to rectangular equivalent.
In wg duct tel.
Design cfm 4 cfm 6 cfm 8 cfm 10 cfm 12 60 6x4 60 4x6 90 4x8 120 4x10 150 4x12 90 8x4 110 6x6 160 6x8 215 6x10 270 6x12 120 10x4 160 8x6 230 8x8 310 8x10 400 8x12 150 12x4 215 10x6 310 10x8 430 10x10 550 10x12 180 14x4 270 12x6 400 12x8 550 12x10 680 12x12 210 16x4 320 14x6 490 14x8 670 14x10 800 14x12 240 18x4 375 16x6 580 16x8 800 16x10 950 16x12 270 20x4 430 18x6 670 18x8 930 18x10 1100.
Failure to do so will result in high velocity and very likely loss of airflow.
Friction rate velocity friction rate.
The chart is based on metal duct.
This equal friction method of duct sizing should be adequate for normal residential furnace heating and air conditioning applications.